<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Trulok &#187; Grip Gages</title>
	<atom:link href="http://www.trulok.com/category/grip-gages/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.trulok.com</link>
	<description></description>
	<lastBuildDate>Mon, 23 Jan 2012 14:01:35 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.2.1</generator>
		<item>
		<title>GG2-XME</title>
		<link>http://www.trulok.com/gg2-xme/</link>
		<comments>http://www.trulok.com/gg2-xme/#comments</comments>
		<pubDate>Mon, 07 Jun 2010 11:43:59 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Grip Gages]]></category>

		<guid isPermaLink="false">http://www.trulok.com/?p=87</guid>
		<description><![CDATA[This is a high precision digital gage for quick and accurate measurement of the structure thickness expressed in grip values or linear values (inch/mm). The modular design allows the gage to expand its measuring range in 16 increments from 0 to 96 grip (0.000 to 6.000 inch) or more. Expressing the measurements in grip values [...]]]></description>
			<content:encoded><![CDATA[<div style="width: 905px; background-color: #efefef; padding: 7px;"> This is a high precision digital gage for quick and accurate measurement of the structure thickness expressed in grip values or linear values (inch/mm). The modular design allows the gage to expand its measuring range in 16 increments from 0 to 96 grip (0.000 to 6.000 inch) or more. Expressing the measurements in grip values eliminates any conversion errors (inch to mm, for example) and gives the operator the ability to select the proper fastener for the given thickness of the structure. This gage was developed to replace the existing scale or mechanical type grip gages in use today. The digital indicator allows the gage to express the readings in grip numbers as expressed in the fastener standards and used by the fastener manufacturing companies. The precision and accuracy of this digital type gage is also much higher than the existing gages in use now.</div>
<table width="100%" cellspacing="10" cellpadding="10">
<tr>
<td valign="top" width="50%">
<h2>Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;Direct reading, no calculations or charts necessary</li>
<li>&nbsp;&nbsp;&nbsp;Accurate, repeatable and reproducible</li>
<li>&nbsp;&nbsp;&nbsp;SPC ready via data port cable</li>
<li>&nbsp;&nbsp;&nbsp;Ease of use with minimal training</li>
<li>&nbsp;&nbsp;&nbsp;Gage and set block calibrated to NIST traceable standards</li>
<li>&nbsp;&nbsp;&nbsp;Unique serial numbers on gages, set blocks and indicators</li>
<li>&nbsp;&nbsp;&nbsp;The components of our gages are made of heat treated wear resistant tool steels and micro finished to ensure accurate and trouble free operation</li>
</ul>
<h2>Digital Indicator S Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;LCD display with rotating bezel</li>
<li>&nbsp;&nbsp;&nbsp;Inch/ mm mode toggle capable</li>
<li>&nbsp;&nbsp;&nbsp;SPC data output ready via data port</li>
<li>&nbsp;&nbsp;&nbsp;Upper and lower tolerance capable</li>
<li>&nbsp;&nbsp;&nbsp;User selectable resolution </li>
<li>&nbsp;&nbsp;&nbsp;Auto power off after 15 minutes of inactivity</li>
<li>&nbsp;&nbsp;&nbsp;Lockout of setup preset (access key)</li>
</ul>
</td>
<td valign="top" width="50%">
<h2>Benefits:</h2>
<p><strong>Physical</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Control installed head height</li>
<li>&nbsp;&nbsp;&nbsp;Better paint adherence</li>
<li>&nbsp;&nbsp;&nbsp;Reduce costly rework</li>
<li>&nbsp;&nbsp;&nbsp;Eliminate panel rejection</li>
<li>&nbsp;&nbsp;&nbsp;Reduce corrosion</li>
</ul>
<p><strong>Process Improvements</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Common gaging method</li>
<li>&nbsp;&nbsp;&nbsp;Implement SPC</li>
<li>&nbsp;&nbsp;&nbsp;Continuous process improvement</li>
<li>&nbsp;&nbsp;&nbsp;Verify tool performance</li>
<li>&nbsp;&nbsp;&nbsp;Control variability</li>
<li>&nbsp;&nbsp;&nbsp;Increase customer satisfaction</li>
</ul>
</td>
</tr>
</table>
<hr />
<h2>Ordering Information:</h2>
<hr />
<p>Trulok&reg; gages are built to your exact specifications. The calibration set block is determined by the required grip range. Please supply us with the following data:</p>
]]></content:encoded>
			<wfw:commentRss>http://www.trulok.com/gg2-xme/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>GGX</title>
		<link>http://www.trulok.com/ggx/</link>
		<comments>http://www.trulok.com/ggx/#comments</comments>
		<pubDate>Mon, 07 Jun 2010 11:43:27 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Grip Gages]]></category>

		<guid isPermaLink="false">http://www.trulok.com/?p=84</guid>
		<description><![CDATA[This is a high precision digital gage for quick and accurate measurement of the structure thickness expressed in grip values. This gage was developed to replace the existing scale or mechanical type grip gages in use today. The digital indicator use allows the gage to express the readings in grip numbers as expressed in the [...]]]></description>
			<content:encoded><![CDATA[<div style="width: 905px; background-color: #efefef; padding: 7px;"> This is a high precision digital gage for quick and accurate measurement of the structure thickness expressed in grip values. This gage was developed to replace the existing scale or mechanical type grip gages in use today. The digital indicator use allows the gage to express the readings in grip numbers as expressed in the fastener standards and used by the fastener manufacturing companies. The precision and accuracy of this digital type gage is also much higher than the existing gages in use now. The fixed range design has the same precision and accuracy as the modular grip gage but it has a fixed grip range 0 to 16 grip (0.000 to 1.000 inch) or 0 to 32 grip (0.000 to 2.000 inch). Expressing the measurements in grip values eliminates any conversion errors (inch to mm, for example) and gives the operator the ability to select the proper fastener  for the given thickness of the structure.
</div>
<table width="100%" cellspacing="10" cellpadding="10">
<tr>
<td valign="top" width="50%">
<h2>Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;Measuring accuracy.001 inch (.025mm)</li>
<li>&nbsp;&nbsp;&nbsp;Direct reading, no calculations or charts necessary</li>
<li>&nbsp;&nbsp;&nbsp;Accurate, repeatable and reproducible</li>
<li>&nbsp;&nbsp;&nbsp;SPC ready via data port cable</li>
<li>&nbsp;&nbsp;&nbsp;Ease of use with minimal training</li>
<li>&nbsp;&nbsp;&nbsp;Gage and set block calibrated to NIST traceable standards</li>
<li>&nbsp;&nbsp;&nbsp;Unique serial numbers on gages, set blocks and indicators</li>
<li>&nbsp;&nbsp;&nbsp;The components of our gages are made of heat treated wear resistant tool steels and micro finished to ensure accurate and trouble free operation</li>
</ul>
<h2>Digital Indicator S Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;LCD display with rotating bezel</li>
<li>&nbsp;&nbsp;&nbsp;Inch/ mm mode toggle capable</li>
<li>&nbsp;&nbsp;&nbsp;SPC data output ready via data port</li>
<li>&nbsp;&nbsp;&nbsp;Upper and lower tolerance capable</li>
<li>&nbsp;&nbsp;&nbsp;User selectable resolution (Mahr-Federal)</li>
<li>&nbsp;&nbsp;&nbsp;Auto power off after 15 minutes of inactivity (Mahr-Federal)</li>
<li>&nbsp;&nbsp;&nbsp;Lockout of setup preset (access key &#8211; Mahr-Federal, computer &#8211; Mitutoyo)</li>
<li>&nbsp;&nbsp;&nbsp;Choice of indicators: Mahr-Federal, or Mitutoyo (please advise of your preference)</li>
</ul>
</td>
<td valign="top" width="50%">
<h2>Benefits:</h2>
<p><strong>Physical</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Control installed head height</li>
<li>&nbsp;&nbsp;&nbsp;Better paint adherence</li>
<li>&nbsp;&nbsp;&nbsp;Reduce costly rework</li>
<li>&nbsp;&nbsp;&nbsp;Eliminate panel rejection</li>
<li>&nbsp;&nbsp;&nbsp;Reduce corrosion</li>
</ul>
<p><strong>Process Improvements</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Common gaging method</li>
<li>&nbsp;&nbsp;&nbsp;Implement SPC</li>
<li>&nbsp;&nbsp;&nbsp;Continuous process improvement</li>
<li>&nbsp;&nbsp;&nbsp;Verify tool performance</li>
<li>&nbsp;&nbsp;&nbsp;Control variability</li>
<li>&nbsp;&nbsp;&nbsp;Increase customer satisfaction</li>
</ul>
</td>
</tr>
</table>
<hr />
<h2>Ordering Information:</h2>
<hr />
<p>Trulok&reg; gages are built to your exact specifications. The calibration set block is determined by the required grip range. Please supply us with the following data:</p>
]]></content:encoded>
			<wfw:commentRss>http://www.trulok.com/ggx/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

