<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Trulok &#187; Flushness Gages</title>
	<atom:link href="http://www.trulok.com/category/flushness-gages/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.trulok.com</link>
	<description></description>
	<lastBuildDate>Mon, 23 Jan 2012 14:01:35 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.2.1</generator>
		<item>
		<title>F1</title>
		<link>http://www.trulok.com/f1/</link>
		<comments>http://www.trulok.com/f1/#comments</comments>
		<pubDate>Mon, 07 Jun 2010 11:40:37 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Flushness Gages]]></category>

		<guid isPermaLink="false">http://www.trulok.com/?p=73</guid>
		<description><![CDATA[The F1 TRULOK&#174; mechanical gage provides a quick and accurate flushness measurement. The .060 inch (1.5mm) flat point stylus is perfect for measuring selected areas of the fastener head for flushness. The base is fixed and has an in ternal ID of .63 inch (16mm). A metric gage F1M is available with a scale between [...]]]></description>
			<content:encoded><![CDATA[<div style="width: 905px; background-color: #efefef; padding: 7px;">
The F1 TRULOK&reg; mechanical gage provides a quick and accurate flushness measurement. The .060 inch (1.5mm) flat point stylus is perfect for measuring selected areas of the fastener head for flushness. The base is fixed and has an in ternal ID of .63 inch (16mm). A metric gage F1M is available with a scale between -0,50 to +0,50. Used in combination with a countersink depth or a diameter gage it provides the user with greater control of the fastener installation process. This versatile gage can check flushness for installed fasteners, welds and grooves.
</div>
<table width="100%" cellspacing="10" cellpadding="10">
<tr>
<td width="50%" valign="top">
<h2>Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;Calibrated inch scale from -.010 to +.025 with .001 inch divisions</li>
<li>&nbsp;&nbsp;&nbsp;Calibrated metric scale from -0.50 to +.050 with .02 mm divisions</li>
<li>&nbsp;&nbsp;&nbsp;Direct contact with the stylus allows pin point selection of the protrusion measurement</li>
<li>&nbsp;&nbsp;&nbsp;Direct reading, measurement remains displayed until the gage is re-zeroed</li>
<li>&nbsp;&nbsp;&nbsp;Accurate, repeatable and reproducible</li>
<li>&nbsp;&nbsp;&nbsp;Ease of use with minimal training</li>
<li>&nbsp;&nbsp;&nbsp;Gage and set block calibrated to NIST traceable standards</li>
<li>&nbsp;&nbsp;&nbsp;Unique serial numbers on gages, set blocks and indicators</li>
<li>&nbsp;&nbsp;&nbsp;F1 is the most rugged, dependable flushness gage</li>
<li>&nbsp;&nbsp;&nbsp;Heat-treated tool steels and micro finished parts ensure accurate and trouble free operation for years to come</li>
</ul>
</td>
<td width="50%" valign="top">
<h2>Benefits:</h2>
<p><strong>Physical</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Control installed head height</li>
<li>&nbsp;&nbsp;&nbsp;Better paint adherence</li>
<li>&nbsp;&nbsp;&nbsp;Reduce costly rework</li>
<li>&nbsp;&nbsp;&nbsp;Eliminate panel rejection</li>
<li>&nbsp;&nbsp;&nbsp;Reduce corrosion</li>
</ul>
<p><strong>Process Improvements</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Common gaging method</li>
<li>&nbsp;&nbsp;&nbsp;Implement SPC</li>
<li>&nbsp;&nbsp;&nbsp;Continuous process improvement</li>
<li>&nbsp;&nbsp;&nbsp;Verify tool performance</li>
<li>&nbsp;&nbsp;&nbsp;Control variability</li>
<li>&nbsp;&nbsp;&nbsp;Increase customer satisfaction</li>
</ul>
</td>
</tr>
</table>
<hr />
<h2>Ordering Information:</h2>
<hr />
<p>x</p>
<h2>Important Note:</h2>
<hr />
<p>* Please specify at time on the purchase order the desired type of base you would like to have on the gage.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.trulok.com/f1/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>FR903</title>
		<link>http://www.trulok.com/fr903/</link>
		<comments>http://www.trulok.com/fr903/#comments</comments>
		<pubDate>Mon, 07 Jun 2010 11:40:12 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Flushness Gages]]></category>

		<guid isPermaLink="false">http://www.trulok.com/?p=70</guid>
		<description><![CDATA[The FR903 is a custom gage that provides a quick and accurate flushness measurement. The flat end stylus is perfect for measuring the highest point of the fastener head for flushness after installation. The contact area of the flat stylus is generally sized to cover approximately 80% of the fastener&#8217;s head. The tripod bases listed [...]]]></description>
			<content:encoded><![CDATA[<div style="width: 905px; background-color: #efefef; padding: 7px;">
The FR903 is a custom gage that provides a quick and accurate flushness measurement. The flat end stylus is perfect for measuring the highest point of the fastener head for flushness after installation. The contact area of the flat stylus is generally sized to cover approximately 80% of the fastener&#8217;s head. The tripod bases listed in the table can be easily interchanged to clear the installed fastener head. This gage could be used in combination with any countersink depth or diameter gages in order to achieve greater control of the fastener installation process.
</div>
<table width="100%" cellspacing="10" cellpadding="10">
<tr>
<td valign="top" width="50%">
<h2>Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;Measuring accuracy .0001 inch (.0025mm)</li>
<li>&nbsp;&nbsp;&nbsp;Direct contact with the stylus allows pin point selection of the protrusion measurement</li>
<li>&nbsp;&nbsp;&nbsp;Direct reading, no calculations or charts necessary</li>
<li>&nbsp;&nbsp;&nbsp;Accurate, repeatable and reproducible</li>
<li>&nbsp;&nbsp;&nbsp;SPC ready via data port cable</li>
<li>&nbsp;&nbsp;&nbsp;Ease of use with minimal training</li>
<li>&nbsp;&nbsp;&nbsp;Gage and set block calibrated to NIST traceable standards</li>
<li>&nbsp;&nbsp;&nbsp;Unique serial numbers on gages, set blocks and indicators</li>
<li>&nbsp;&nbsp;&nbsp;The components of our gages are made of heat treated wear resistant tool steels and micro finished to ensure accurate and trouble free operation</li>
</ul>
<h2>Digital Indicator Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;LCD display with rotating bezel</li>
<li>&nbsp;&nbsp;&nbsp;Inch/ mm mode toggle capable</li>
<li>&nbsp;&nbsp;&nbsp;SPC data output ready via data port</li>
<li>&nbsp;&nbsp;&nbsp;Upper and lower tolerance capable</li>
<li>&nbsp;&nbsp;&nbsp;User selectable resolution</li>
</ul>
</td>
<td valign="top" width="50%">
<h2>Benefits:</h2>
<p><strong>Physical</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Control installed head height</li>
<li>&nbsp;&nbsp;&nbsp;Better paint adherence</li>
<li>&nbsp;&nbsp;&nbsp;Reduce costly rework</li>
<li>&nbsp;&nbsp;&nbsp;Eliminate panel rejection</li>
<li>&nbsp;&nbsp;&nbsp;Reduce corrosion</li>
</ul>
<p><strong>Process Improvements</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Common gaging method</li>
<li>&nbsp;&nbsp;&nbsp;Implement SPC</li>
<li>&nbsp;&nbsp;&nbsp;Continuous process improvement</li>
<li>&nbsp;&nbsp;&nbsp;Verify tool performance</li>
<li>&nbsp;&nbsp;&nbsp;Control variability</li>
<li>&nbsp;&nbsp;&nbsp;Increase customer satisfaction</li>
</ul>
</td>
</tr>
</table>
<hr />
<h2>Ordering Information:</h2>
<hr />
<p>Trulok&reg; gages are built to your exact specifications. The size of the flat (zero) set block is determined by the size and base configuration. Please supply us with the following data:</p>
]]></content:encoded>
			<wfw:commentRss>http://www.trulok.com/fr903/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>FR902</title>
		<link>http://www.trulok.com/fr902/</link>
		<comments>http://www.trulok.com/fr902/#comments</comments>
		<pubDate>Mon, 07 Jun 2010 11:39:50 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Flushness Gages]]></category>

		<guid isPermaLink="false">http://www.trulok.com/?p=68</guid>
		<description><![CDATA[The FR902 is a custom flushness gage that provides a quick and accurate flushness measurement. The &#8709; .060 inch (1.5 mm) flat point stylus is perfect for measuring selected areas of the fastener head for flushness. The tripod bases listed in the table can be easily interchanged to clear the installed fastener head. This gage [...]]]></description>
			<content:encoded><![CDATA[<div style="width: 905px; background-color: #efefef; padding: 7px;">
The FR902 is a custom flushness gage that provides a quick and accurate flushness measurement. The &#8709; .060 inch (1.5 mm) flat point stylus is perfect for measuring selected areas of the fastener head for flushness. The tripod bases listed in the table can be easily interchanged to clear the installed fastener head. This gage could be used in combination with any countersink depth or diameter gages in order to achieve greater control of the fastener installation process.
</div>
<table width="100%" cellspacing="10" cellpadding="10">
<tr>
<td valign="top" width="50%">
<h2>Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;Measuring accuracy .0001 inch (.0025mm)</li>
<li>&nbsp;&nbsp;&nbsp;Direct contact with the stylus allows pin point selection of the protrusion measurement</li>
<li>&nbsp;&nbsp;&nbsp;Direct reading, no calculations or charts necessary</li>
<li>&nbsp;&nbsp;&nbsp;Accurate, repeatable and reproducible</li>
<li>&nbsp;&nbsp;&nbsp;SPC ready via data port cable</li>
<li>&nbsp;&nbsp;&nbsp;Ease of use with minimal training</li>
<li>&nbsp;&nbsp;&nbsp;Gage and set block calibrated to NIST traceable standards</li>
<li>&nbsp;&nbsp;&nbsp;Unique serial numbers on gages, set blocks and indicators</li>
<li>&nbsp;&nbsp;&nbsp;The components of our gages are made of heat treated wear resistant tool steels and micro finished to ensure accurate and trouble free operation</li>
</ul>
<h2>Digital Indicator Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;LCD display with rotating bezel</li>
<li>&nbsp;&nbsp;&nbsp;Inch/ mm mode toggle capable</li>
<li>&nbsp;&nbsp;&nbsp;SPC data output ready via data port</li>
<li>&nbsp;&nbsp;&nbsp;Upper and lower tolerance capable</li>
<li>&nbsp;&nbsp;&nbsp;User selectable resolution</li>
</ul>
</td>
<td valign="top" width="50%">
<h2>Benefits:</h2>
<p><strong>Physical</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Control installed head height</li>
<li>&nbsp;&nbsp;&nbsp;Better paint adherence</li>
<li>&nbsp;&nbsp;&nbsp;Reduce costly rework</li>
<li>&nbsp;&nbsp;&nbsp;Eliminate panel rejection</li>
<li>&nbsp;&nbsp;&nbsp;Reduce corrosion</li>
</ul>
<p><strong>Process Improvements</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Common gaging method</li>
<li>&nbsp;&nbsp;&nbsp;Implement SPC</li>
<li>&nbsp;&nbsp;&nbsp;Continuous process improvement</li>
<li>&nbsp;&nbsp;&nbsp;Verify tool performance</li>
<li>&nbsp;&nbsp;&nbsp;Control variability</li>
<li>&nbsp;&nbsp;&nbsp;Increase customer satisfaction</li>
</ul>
</td>
</tr>
</table>
<hr />
<h2>Ordering Information:</h2>
<hr />
<p>Trulok&reg; gages are built to your exact specifications. The size of the flat (zero) set block is determined by the size and base configuration. Please supply us with the following data:</p>
]]></content:encoded>
			<wfw:commentRss>http://www.trulok.com/fr902/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>FR901</title>
		<link>http://www.trulok.com/fr901/</link>
		<comments>http://www.trulok.com/fr901/#comments</comments>
		<pubDate>Mon, 07 Jun 2010 11:39:17 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Flushness Gages]]></category>

		<guid isPermaLink="false">http://www.trulok.com/?p=66</guid>
		<description><![CDATA[The FR901 is a custom gage that provides a quick and accurate flushness measurement. The sized flat end stylus is perfect for measuring the highest point of the fastener head for flushness after installation. The contact area of the flat stylus is generally sized to cover approximately 80% of the fastener&#8217;s head. The base is [...]]]></description>
			<content:encoded><![CDATA[<div style="width: 905px; background-color: #efefef; padding: 7px;">
The FR901 is a custom gage that provides a quick and accurate flushness measurement. The sized flat end stylus is perfect for measuring the highest point of the fastener head for flushness after installation. The contact area of the flat stylus is generally sized to cover approximately 80% of the fastener&#8217;s head. The base is fixed and it has a predetermined ID and OD to clear the installed fastener head and the surrounding structure. This gage could be used in combination with any countersink depth or diameter gages in order to achieve greater control of the fastener installation process.
</div>
<table width="100%" cellspacing="10" cellpadding="10">
<tr>
<td valign="top" width="50%">
<h2>Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;Measuring accuracy .0001 inch (.0025mm)</li>
<li>&nbsp;&nbsp;&nbsp;Direct contact with the stylus allows pin point selection of the protrusion measurement</li>
<li>&nbsp;&nbsp;&nbsp;Direct reading, no calculations or charts necessary</li>
<li>&nbsp;&nbsp;&nbsp;Accurate, repeatable and reproducible</li>
<li>&nbsp;&nbsp;&nbsp;SPC ready via data port cable</li>
<li>&nbsp;&nbsp;&nbsp;Ease of use with minimal training</li>
<li>&nbsp;&nbsp;&nbsp;Gage and set block calibrated to NIST traceable standards</li>
<li>&nbsp;&nbsp;&nbsp;Unique serial numbers on gages, set blocks and indicators</li>
<li>&nbsp;&nbsp;&nbsp;The components of our gages are made of heat treated wear resistant tool steels and micro finished to ensure accurate and trouble free operation</li>
</ul>
<h2>Digital Indicator Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;LCD display with rotating bezel</li>
<li>&nbsp;&nbsp;&nbsp;Inch/ mm mode toggle capable</li>
<li>&nbsp;&nbsp;&nbsp;SPC data output ready via data port</li>
<li>&nbsp;&nbsp;&nbsp;Upper and lower tolerance capable</li>
<li>&nbsp;&nbsp;&nbsp;User selectable resolution</li>
</ul>
</td>
<td valign="top" width="50%">
<h2>Benefits:</h2>
<p><strong>Physical</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Control installed head height</li>
<li>&nbsp;&nbsp;&nbsp;Better paint adherence</li>
<li>&nbsp;&nbsp;&nbsp;Reduce costly rework</li>
<li>&nbsp;&nbsp;&nbsp;Eliminate panel rejection</li>
<li>&nbsp;&nbsp;&nbsp;Reduce corrosion</li>
</ul>
<p><strong>Process Improvements</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Common gaging method</li>
<li>&nbsp;&nbsp;&nbsp;Implement SPC</li>
<li>&nbsp;&nbsp;&nbsp;Continuous process improvement</li>
<li>&nbsp;&nbsp;&nbsp;Verify tool performance</li>
<li>&nbsp;&nbsp;&nbsp;Control variability</li>
<li>&nbsp;&nbsp;&nbsp;Increase customer satisfaction</li>
</ul>
</td>
</tr>
</table>
<hr />
<h2>Ordering Information:</h2>
<hr />
<p>Trulok&reg; gages are built to your exact specifications. The size of the flat (zero) set block is determined by the size and base configuration. Please supply us with the following data:</p>
]]></content:encoded>
			<wfw:commentRss>http://www.trulok.com/fr901/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>FR900</title>
		<link>http://www.trulok.com/fr900/</link>
		<comments>http://www.trulok.com/fr900/#comments</comments>
		<pubDate>Mon, 07 Jun 2010 11:38:50 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Flushness Gages]]></category>

		<guid isPermaLink="false">http://www.trulok.com/?p=64</guid>
		<description><![CDATA[The FR900 gage provides a quick and accurate flushness measurement. The .060 inch (1.5 mm) flat point stylus is perfect for measuring selected areas of the fastener head for flushness. The base is fixed and it has an internal ID of .63 inch (16 mm). Used in combination with a countersink depth or a diameter [...]]]></description>
			<content:encoded><![CDATA[<div style="width: 905px; background-color: #efefef; padding: 7px;">
The FR900 gage provides a quick and accurate flushness measurement. The .060 inch (1.5 mm) flat point stylus is perfect for measuring selected areas of the fastener head for flushness. The base is fixed and it has an internal ID of .63 inch (16 mm). Used in combination with a countersink depth or a diameter gage provides the user with greater control of the fastener installation process. This versatile gage can check flushness for fasteners, welds and grooves.
</div>
<table width="100%" cellspacing="10" cellpadding="10">
<tr>
<td valign="top" width="50%">
<h2>Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;Measuring accuracy .0001 inch (.0025mm)</li>
<li>&nbsp;&nbsp;&nbsp;Direct contact with the stylus allows pin point selection of the protrusion measurement</li>
<li>&nbsp;&nbsp;&nbsp;Direct reading, no calculations or charts necessary</li>
<li>&nbsp;&nbsp;&nbsp;Accurate, repeatable and reproducible</li>
<li>&nbsp;&nbsp;&nbsp;SPC ready via data port cable</li>
<li>&nbsp;&nbsp;&nbsp;Ease of use with minimal training</li>
<li>&nbsp;&nbsp;&nbsp;Gage and set block calibrated to NIST traceable standards</li>
<li>&nbsp;&nbsp;&nbsp;Unique serial numbers on gages, set blocks and indicators</li>
<li>&nbsp;&nbsp;&nbsp;The components of our gages are made of heat treated wear resistant tool steels and micro finished to ensure accurate and trouble free operation</li>
</ul>
<h2>Digital Indicator Features:</h2>
<ul>
<li>&nbsp;&nbsp;&nbsp;LCD display with rotating bezel</li>
<li>&nbsp;&nbsp;&nbsp;Inch/ mm mode toggle capable</li>
<li>&nbsp;&nbsp;&nbsp;SPC data output ready via data port</li>
<li>&nbsp;&nbsp;&nbsp;Upper and lower tolerance capable</li>
<li>&nbsp;&nbsp;&nbsp;User selectable resolution</li>
</ul>
</td>
<td valign="top" width="50%">
<h2>Benefits:</h2>
<p><strong>Physical</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Control installed head height</li>
<li>&nbsp;&nbsp;&nbsp;Better paint adherence</li>
<li>&nbsp;&nbsp;&nbsp;Reduce costly rework</li>
<li>&nbsp;&nbsp;&nbsp;Eliminate panel rejection</li>
<li>&nbsp;&nbsp;&nbsp;Reduce corrosion</li>
</ul>
<p><strong>Process Improvements</strong></p>
<ul>
<li>&nbsp;&nbsp;&nbsp;Common gaging method</li>
<li>&nbsp;&nbsp;&nbsp;Implement SPC</li>
<li>&nbsp;&nbsp;&nbsp;Continuous process improvement</li>
<li>&nbsp;&nbsp;&nbsp;Verify tool performance</li>
<li>&nbsp;&nbsp;&nbsp;Control variability</li>
<li>&nbsp;&nbsp;&nbsp;Increase customer satisfaction</li>
</ul>
</td>
</tr>
</table>
<hr />
<h2>Ordering Information:</h2>
<hr />
<p>Trulok&reg; gages are built to your exact specifications. The size of the flat (zero) set block is determined by the size and base configuration. Please supply us with the following data:</p>
]]></content:encoded>
			<wfw:commentRss>http://www.trulok.com/fr900/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>